Description Usage Arguments Value
reads mzXML files from a directory extracts metadata info,
groups ion signals with signalGrouping
, filters noise
dynamically
dynamicNoiseFilter
and identifies precursor ion charge state,
by isotopic pattern.
1 2 3 4 5 6 | adductSpecGen(mzXmlDir=NULL, runOrder=NULL, nCores=NULL,
intStdMass=834.77692,intStdPeakList=c(290.21, 403.30, 516.38,
587.42,849.40, 884.92, 958.46, 993.97,1050.52, 1107.06, 1209.73,
1337.79,1465.85),TICfilter=10000, DNF=2, minInt=300,
minPeaks=5,intStd_MaxMedRtDrift=360, intStd_MaxPpmDev=200,minSpecEx=40,
outputPlotDir=NULL)
|
mzXmlDir |
character a full path to a directory containing either .mzXML or .mzML data |
runOrder |
character a full path to a csv file specifying the runorder for each of the files the first column must contain the precise file name and the second column an integer representing the precise run order. |
nCores |
numeric the number of cores to use for parallel computation. The default is to 1 core |
intStdMass |
numeric vector of the mass of the internal standard. Default is the mass of |
intStdPeakList |
numeric vector of masses for the internal standard peaks |
TICfilter |
numeric minimimum total ion current of an MS/MS scan. Any MS/MS scan below this value will be filtered out (default=0). |
DNF |
dynamic noise filter minimum signal to noise threshold (default = 2), calculated as the ratio between the linear model predicted intensity value and the actual intensity. |
minInt |
numeric minimum intensity value |
minPeaks |
minimum number of signal peaks following dynamic noise filtration (default = 5). |
intStd_MaxMedRtDrift |
numeric the maximum retention time drift window (in seconds) to identify internal standard MS/MS spectrum scans (default = 600). |
intStd_MaxPpmDev |
numeric the maximum mass accuracy window (in ppm). to identify internal standard MS/MS spectrum scans (default = 200 ppm). |
minSpecEx |
numeric the minimum percentage of the total ion current explained by the internal standard fragments (default = 40). Sometime spectra are not identified due to this cutoff being set too high. If unexpected datapoints have been interpolated then reduce this value. |
outputPlotDir |
character string for the output directory for plots, default is working directory. |
AdductSpec object
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.