Description Usage Arguments Value Author(s) References Examples
Extract information for data quanlity control: detection P values, number of beads and averaged bisulfite conversion intensity. The function can also identify low quality samples and probes, as well as outlier samples in total intensity or beta value distribution.
1 2 |
rgSet |
An object of class |
detPthre |
Detection P value threshold to identify low quality data point |
detPtype |
Calculate detection P values based on negtive internal control ("negative") probes or out of the band ("oob") probes |
nbthre |
Number of bead threshold to identify data point of low quality |
samplethre |
Threshold to identify samples with low data quality, the percentage of low quality methylation data points across probes for each sample |
CpGthre |
Threshold to identify probes with low data quality, percentage of low quality methylation data points across samples for each probe |
bisulthre |
Threshold of bisulfite intensity for identification of low quality samples. By default, Mean - 3 x SD of sample bisufite control intensities will be used as a threshold. |
outlier |
If TRUE, outlier samples in total intensity or beta value distribution will be idenfied and classified as bad samples. |
distplot |
TRUE or FALSE, whether to produce beta value distribution plots before and after QC. |
detP: a matrix of detection P values
nbead: a matrix for number of beads
bisul: a vector of averaged intensities for bisulfite conversion controls per sample
badsample: a list of low quality or outlier samples
badCpG: a list of low quality CpGs
outlier_sample: a list of outlier samples in methylation beta value or totol intensity distribution.
Figure "qc_sample.jpg": scatter plot of Percent of low quality data per sample vs. Average bisulfite conversion intensity
Figure "qc_CpG.jpg": histogram for Percent of low quality data per CpG.
Figure "freqpolygon_beta_beforeQC.jpg": distribution plot of input data, samples colored in red are "bad" samples, list in badsample, including samples with low data quality and outlier in methylaiton beta value or total intensity.
Figure "freqpolygon_beta_afterQC.jpg": distribution plot input data after filtering "bad" samples.
Zongli Xu
Zongli Xu, Liang Niu, Leping Li and Jack A. Taylor, ENmix: a novel background correction method for Illumina HumanMethylation450 BeadChip. Nucleic Acids Research 2015.
1 2 3 4 5 6 7 8 9 10 11 12 | if (require(minfiData)) {
#rgDataSet as input
path <- file.path(find.package("minfiData"),"extdata")
rgSet <- readidat(path = path,recursive = TRUE)
qc=QCinfo(rgSet)
#RGChannelSetExtended as input
sheet <- read.metharray.sheet(file.path(find.package("minfiData"),"extdata"),
pattern = "csv$")
rgSet <- read.metharray.exp(targets = sheet,extended = TRUE)
qc<-QCinfo(rgSet)
}
|
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.