knitr::opts_chunk$set( collapse = TRUE, comment = "#>", # fig.width = 7, # fig.height = 5, warning = FALSE, message = TRUE, out.width = "100%" )
metflow2 can used to processed the raw MS data for peak detection and alignment, and generate a peak table for next analysis.
The MS raw data from Mass Spectrometry should be converted to mzXML
format and then placed in different folders according to their class, for example Subject
, QC
, and Blank
samples.
Here we use the demo data from demoData
packages. So please install demoData
package first.
devtools::install_github("jaspershen/demoData")
You can convert raw MS data to mzXML format using ProteoWizard
software. And the parameter setting is shown the below figure:
All the mzXML
format files should be placed in different folder according to sample type, such as QC
, Subject
, and Blank
.
processData()
functionWe use the demo data from demoData
to show how to process raw MS data using metflow2
.
First we load the demo data from demoData
package and then place them in a example
folder.
library(demoData) library(metflow2) library(tidyverse) library(xcms) library(MSnbase) library(mzR)
##create a folder named as `example` path <- file.path(".", "example") dir.create(path = path, showWarnings = FALSE)
##get demo data mzxml_data <- system.file("mzxml", package = "demoData") file.copy(from = file.path(mzxml_data, "POS"), to = path, overwrite = TRUE, recursive = TRUE)
Now the demo mzXML data is in the ./example/POS
folder. There are two folder in this directory, namely Subject
and QC
.
Next, we use the process_data()
function for peak detection and alignment.
new_path <- file.path(path, "POS") setwd(path) metflow2::process_data( path = ".", polarity = "positive", ppm = 15, peakwidth = c(5, 30), snthresh = 5, noise = 500, threads = 6, output.tic = TRUE, output.bpc = TRUE, output.rt.correction.plot = TRUE, min.fraction = 0.5, fill.peaks = FALSE, is.table = "is.xlsx", group.for.figure = "QC" )
Some important arguments:
ppm
: Peak detection ppm. See the xcms
package.
peakwidth
: Peak width. It is dependent on your column and LC system. See the xcms
package.
snthresh
: Singal to noise threshold. See the xcms
package.
noise
: Noise cutiff. See the xcms
package.
threads
: The core number for performing.
output.tic
, output.bpc
, and group.for.figure
: Do you want to output the TIC or BPC of samples? Some times there are a lot of samples, so you can set the group.for.figure
as the group name, for example, you can set it as QC
.
min.fraction
: If one peak appears more than min.fraction
sample in at least one group samples it will be kept.
fill.peaks
: Do you want to fill the missing values (NA)?
is.table
: If you add internal standards in your samples, you can provide the the is.table
in the folder which your mzXML format data in. It must be xlsx
format like the below figure shows:
![](../man/figures/Screen Shot 2020-04-01 at 10.11.33 AM.png)
Ohter parameters you can find here: processData()
.
After all done, all the results are placed in a new folder named as Result
.
![](../man/figures/Screen Shot 2020-04-01 at 1.00.38 PM.png)
* Peak_table.csv
: is the peak table for next analysis.
![](../man/figures/Screen Shot 2020-04-01 at 1.09.52 PM.png)
Peak_table_for_cleaning.csv
: Some non-useful columns is deleted from the Peak_table.csv
, this can be directory used for next data cleaning.![](../man/figures/Screen Shot 2020-04-01 at 1.07.37 PM.png)
intermediate_data
: This is a folder which contains some intermediate data. If you want to re-run the data processing, please delete this folder first.
feature_EIC
: If you provide the internal standard table, the EICs of all the ISs will be placed in this folder.
From the EICs of the internal standards, you can access the quality of data.
Add the following code to your website.